-, PRAMUDITA BUDIUTOMO PENGARUH PENGGUNAAN EXHAUST FAN TERHADAP VISIBILITAS DAN KESELAMATAN PERSONEL DALAM OPERASI KEBAKARAN DI BANDAR UDARA SOEKARNO-HATTA JAKARTA. PENGARUH PENGGUNAAN EXHAUST FAN TERHADAP VISIBILITAS DAN KESELAMATAN PERSONEL DALAM OPERASI KEBAKARAN DI BANDAR UDARA SOEKARNO-HATTA JAKARTA, 14 (2). ISSN 2302-2205 // 2808-7321 (Submitted)
![[thumbnail of TUGAS AKHIR]](http://repository.ppicurug.ac.id/style/images/fileicons/text.png)
DIII PKP16A_PRAMUDITA BUDIUTOMO_TUGAS AKHIR_2025.pdf - Published Version
Restricted to Registered users only
Download (3MB) | Request a copy
Abstract
Keselamatan personel dalam operasi kebakaran, khususnya di area terminal bandar udara yang bersifat tertutup, sangat dipengaruhi oleh visibilitas dan kualitas udara. Salah satu upaya mitigasi risiko yang dilakukan adalah dengan penggunaan exhaust fan portable. Penelitian ini bertujuan untuk menganalisis pengaruh penggunaan exhaust fan terhadap visibilitas dan keselamatan personel pemadam kebakaran (ARFF) di Bandar Udara Internasional Soekarno-Hatta. Metode penelitian yang digunakan adalah kuantitatif dengan pendekatan survei melalui penyebaran kuesioner berbasis skala Likert kepada 146 personel ARFF. Hasil uji validitas, reliabilitas, normalitas, dan regresi linier menunjukkan bahwa penggunaan exhaust fan berpengaruh secara signifikan terhadap peningkatan visibilitas dan keselamatan personel selama operasi kebakaran. Persamaan regresi yang diperoleh menunjukkan bahwa setiap peningkatan penggunaan exhaust fan berdampak positif terhadap kedua variabel dependen. Nilai R² sebesar 62,7% untuk keselamatan personel dan 47,9% untuk visibilitas menunjukkan bahwa penggunaan exhaust fan berkontribusi besar dalam menciptakan lingkungan kerja yang lebih aman dan efisien. Penelitian ini merekomendasikan optimalisasi pemeliharaan dan penempatan strategis exhaust fan sebagai bagian dari prosedur standar operasi darurat di bandar udara.
Kata Kunci: exhaust fan, visibilitas, keselamatan personel, kebakaran, ARFF, Bandar Udara Soekarno-Hatta
Personnel safety during fire operations, particularly in enclosed airport terminal areas, is highly influenced by visibility and air quality. One risk mitigation measure is the use of portable exhaust fans. This study aims to analyze the effect of exhaust fan usage on visibility and firefighter (ARFF) safety at Soekarno-Hatta International Airport. A quantitative method was employed, using surveys distributed via Likert-scale questionnaires to 146 ARFF personnel. The results of validity, reliability, normality, and linear regression tests indicate that the use of exhaust fans significantly improves both visibility and personnel safety during fire operations. The regression analysis shows that each increase in exhaust fan usage positively affects the dependent variables. The R² value of 62.7% for personnel safety and 47.9% for visibility demonstrates that exhaust fan use contributes greatly to creating a safer and more efficient working environment. This study recommends optimizing the maintenance and strategic placement of portable exhaust fans as part of standard emergency operating procedures in airport fire response.
Keywords: exhaust fan, visibility, personnel safety, fire, ARFF, Soekarno-Hatta Airport
Item Type: | Article |
---|---|
Uncontrolled Keywords: | exhaust fan, visibilitas, keselamatan personel, kebakaran, ARFF, Bandar Udara Soekarno-Hatta, exhaust fan, visibility, personnel safety, fire, ARFF, Soekarno-Hatta Airport |
Subjects: | H Social Sciences > HE Transportation and Communications |
Divisions: | DIII Pertolongan Kecelakaan Pesawat |
Depositing User: | Mr. Pramudita Budiutomo |
Date Deposited: | 04 Sep 2025 02:39 |
Last Modified: | 04 Sep 2025 02:39 |
URI: | http://repository.ppicurug.ac.id/id/eprint/676 |